10 in CMU bearing wall

A plain reinforced block bearing wall, grouted at the bars.

A plain reinforced block bearing wall, grouted at the bars.

Layers, in order

#LayerThicknessSpacing
110 in block and mortar9 5/8 in
2Grout and reinforcing6 5/8 inat 48 in o.c.

Build steps

  1. Lay the block (Mason). Flashing and weep vents at the base course, then the block in mortar, course by course.
  2. Reinforce and grout (Mason). Joint reinforcement as the block rises, bars in the cells, bond beam, grout.

Materials per 100 sf of wall

From the takeoff of Setout's sample building, across every wall of this type on the typical floors, after doors and windows are cut out. Use it to sanity-check a bid, not as a substitute for a takeoff.

MaterialPer 100 sf
10" CMU block, lightweight ASTM C90, standard units105 ea
9 ga 2-leg joint reinforcement, 16" o.c., 10" wall74.1 lf
#5 vertical rebar (ASTM A615 Gr 60), incl. laps39.0 lf
#5 bond beam rebar, 2 continuous (ASTM A615 Gr 60), incl. laps23.7 lf
10" CMU block, lightweight ASTM C90, bond beam units7.9 ea
#5 x 5'-0" L-bars at slab, 48" o.c.3.3 ea
Portland cement for Type S mortar, 94 lb bags3.2 ea
Hydrated lime for mortar, 50 lb bags1.3 ea
Mason sand for mortar0.35 cy
Fine grout, 4,000 psi (ASTM C476)0.28 cy